Error Code C1

The vent blockage test found a problem with your exhaust

Moderate

Address soon - your appliance may not work properly

Also displayed as: C1

What This Means

Items left inside the drum during Vent Blockage Test; Dry sensor (moisture sensor) short or open; Faulty moisture sensor wiring

What actually causes this:

During the Smart Install vent test, the dryer found the exhaust vent is too restricted for safe operation.

First Thing to Check

Check the exhaust vent hose behind the dryer — make sure it's not kinked, crushed, or full of lint.

Parts Involved

Moisture SensorDrum

How to Fix

  1. 1

    1. Remove items from the drum and check again

  2. 2

    2. Check the dry sensor for short or open circuit

  3. 3

    3. Run the Vent Blockage Test with an empty drum

Need more help with your Samsung DVE45T3400W?