Error Code HC

Your dryer isn't heating properly or is overheating

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: HC

What This Means

Thermistor resistance out of range; Restricted vent system causing excessive heat buildup; Heater malfunction; Thermostat failure; Clogged lint screen

What actually causes this:

Most often caused by a clogged exhaust vent that traps hot air inside the dryer, or the heating element has burned out.

First Thing to Check

Check your exhaust vent — disconnect it from the back of the dryer and look for lint buildup inside.

Parts Involved

ThermistorThermostat 1Thermostat 2Thermostat 3 (Thermal Cut-off)Heater AssemblyMain PCB

How to Fix

  1. 1

    1. Check the PCB and thermistor

  2. 2

    2. Measure thermistor resistance: should be 10K ohms at 25C (77F)

  3. 3

    3. Check thermostat 1 resistance: should be < 1 ohm (infinity means replace)

  4. 4

    4. Check thermostat 2 resistance: should be < 1 ohm (infinity means replace)

  5. 5

    5. Check thermostat 3 (thermal cut-off) resistance: should be < 1 ohm

  6. 6

    6. Check heater resistance: SINGLE electric heater 10 ohms (PIN 1-3), DUAL gas heater 13 ohms (PIN 2-3)

  7. 7

    7. Check exhaust vent system for restrictions or blockages