Error Code dC
The dryer thinks the door is open while running
Moderate
Address soon - your appliance may not work properly
Also displayed as: dC
What This Means
Door not fully closed or latched; Door sensor unit is loose; Door sensor unit is shorted; Loose wire terminals in door sense circuit
What actually causes this:
Door wasn't closed firmly, or the door switch has gone bad from normal wear.
First Thing to Check
Open and firmly close the door, then try starting it again.
Parts Involved
How to Fix
- 1
1. Close the door firmly and run the dryer again
- 2
2. Inspect the door sensor unit for looseness or damage
- 3
3. Test door switch: Door open -- COM-NC (pins 1-3) should be < 1 ohm, COM-NO (pins 1-2) should be infinity
- 4
4. Test door switch: Door closed -- COM-NC (pins 1-3) should be infinity, COM-NO (pins 1-2) should be < 1 ohm
- 5
5. If door sensor unit is loose or shorted, repair or replace