Error Code HC

Your dryer isn't heating properly or is overheating

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: HC

What This Means

Restricted vent system causing excessive heat buildup; Thermistor resistance out of range; Heater malfunction; Thermostat failure; PCB failure

What actually causes this:

Most often caused by a clogged exhaust vent that traps hot air inside the dryer, or the heating element has burned out.

First Thing to Check

Check your exhaust vent — disconnect it from the back of the dryer and look for lint buildup inside.

Parts Involved

Main PCBThermistorThermostat 2Thermostat 3Heater Assembly

How to Fix

  1. 1

    1. Check the PCB and thermistor for proper operation

  2. 2

    2. Measure thermistor resistance: should be 10K ohm at 25 deg C (electric) or 238.23K ohm at 25 deg C (gas)

  3. 3

    3. Check thermostat resistance: should be < 1 ohm (infinity means replace)

  4. 4

    4. Check heater resistance: DUAL heater -- 13 ohm (PIN 2-3), 34 ohm (PIN 1-2); SINGLE heater -- 10 ohm (PIN 1-3)

  5. 5

    5. Check exhaust vent system for restrictions

  6. 6

    6. If resistance is infinity on any component, replace the faulty component

Parts Commonly Needed for This Error

OEM part numbers confirmed by retailers

Need more help with your Samsung DVG54R7600W?