Error Code C1
The vent blockage test found a problem with your exhaust
Moderate
Address soon - your appliance may not work properly
Also displayed as: C1
What This Means
Items left inside the drum during vent blockage test; Dry sensor (moisture sensor) malfunction
What actually causes this:
During the Smart Install vent test, the dryer found the exhaust vent is too restricted for safe operation.
First Thing to Check
Check the exhaust vent hose behind the dryer — make sure it's not kinked, crushed, or full of lint.
Parts Involved
How to Fix
- 1
1. Remove all items from the drum
- 2
2. Check the dry sensor (moisture sensor) for proper operation
- 3
3. Rerun the Smart Install vent blockage test
Other Error Codes for DVG55CG7500EA3
Your dryer's temperature sensor isn't reading correctly
A secondary temperature sensor is giving bad readings
The door switch isn't working properly
The dryer thinks the door is open while running
Your dryer detected restricted airflow during a vent test
Your dryer is getting the wrong type of electrical power
The dryer's internal parts aren't communicating properly
Your dryer vent is about 80% blocked