Error Code tE
Thermal Error - thermistor resistance output abnormal
Moderate
Address soon - your appliance may not work properly
What This Means
Wiring connection issue at RD6 to WH4; Thermistor resistance out of range (should be 8-44 kohms)
How to Fix
- 1
Check if connector is connected to main PCB (RD6 to WH4); replace thermistor if disconnected
- 2
Check thermistor resistance (8-44 kohms); replace thermistor if out of range
- 3
Check voltage at RD6 pin3 to NA8 pin3 (should be 1-3V DC)
- 4
Replace main PCB assembly if all components check out
This Error Applies To
LG LDP6797ST Series Dishwashers
Related Error Codes
Leakage Error - internal leakage detected
Excess Error - water fills above normal level (drain pump operates automatically)
Inlet Error - unit does not reach normal water level
Vario Error - position of vario cam not detected properly
NFC or Wi-Fi Module failure (displayed during test mode when Power+Start pressed once)
Bubble Error - oversudsing detected
EEPROM failure (displayed during test mode - Start pressed 1 time after entering test mode)
Heater Error - water not heated or tub overheated above 194 degrees F