Temperature sensor (thermistor) failure — open circuit
Moderate
Address soon - your appliance may not work properly
Also displayed as: tE1
How to Fix
- 1
Power off the dryer immediately.
- 2
Enter diagnostic mode: press Power then immediately press Temp and Time; press START/PAUSE to advance.
- 3
Note tE1 displayed during diagnostic confirms thermistor open.
- 4
Disconnect power and discharge capacitors by touching metal plug of power cord to ground.
- 5
Remove NA6 connector from the main PCB.
- 6
Short Pin 2 (Blue wire) and Pin 4 (Orange wire) of NA6 connector together with a metal jumper.
- 7
If tE1 clears after shorting, the fault is in the thermistor or its wiring harness — not the PCB.
- 8
Separate the thermistor harness connector and measure resistance across terminals.
- 9
Compare resistance to Table 1: at 50°F (10°C) expect 18.0 kΩ; at 70°F (27°C) expect 9.3 kΩ; at 100°F (38°C) expect 6.2 kΩ; at 130°F (54°C) expect 2.9 kΩ.
- 10
If resistance is out of range or open (infinite), replace the thermistor assembly.
- 11
If resistance is in range, inspect the harness-linking connector for corrosion, bent pins, or broken wires.
- 12
If connector and harness pass inspection, reconnect NA6 and verify control connector seating.
- 13
If fault persists with good thermistor and wiring, replace the main PCB (controller).
- 14
Restore power and verify normal operation; confirm no tE1 recurrence.
This Error Applies To
LG DLE8400BE Series Dryers (2023) (2023–present)
Related Error Codes
Power supply error — electric dryer power cord not connected correctly or house power supply incorrect; also displayed when 240V is applied to PCB indicating mis-wired power cord
Duct blockage — ductwork approximately 90% blocked (displayed for 2 hours only)
Power failure — house fuse blown, circuit breaker tripped, or power outage
Duct blockage — ductwork approximately 95% blocked (displayed for 2 hours only)
Temperature sensor (thermistor) failure — shorted circuit
No power / power code error — outlet voltage issue or power cord not properly connected
Flow Sense duct blockage restriction detected after drying cycle ends