Error Code bE
Sensors do not detect that steam generator is full within 60 seconds
Moderate
Address soon - your appliance may not work properly
Also displayed as: bE
How to Fix
- 1
Check that the steam feeder drawer is filled with water to the MAX line.
- 2
Do not use distilled water — the water level sensor requires mineral content to operate.
- 3
Ensure the steam feeder is fully seated and the drawer is completely closed.
- 4
Turn the dryer off, refill the feeder to MAX, then restart the steam cycle.
- 5
If error persists after correct water level is confirmed: check water pump operation (see tE5 / Test 8).
- 6
If pump is defective: replace the DC water supply pump.
- 7
If pump is normal but error persists: replace the steam generator assembly.
This Error Applies To
LG DLEX3570V Series Dryers
Related Error Codes
No power / power supply fault
EEPROM operation is abnormal
Pump valve resistance less than 10 in test mode; pump circuit fault
Outlet thermistor open or shorted
Outlet thermistor open or shorted (short circuit variant)
Electric dryer power cord not connected correctly or house power supply is incorrect
NFC module open or shorted
Steam generator thermistor open or shorted