LG Dryers

Error Code tE1

Outlet thermistor open or shorted

Moderate

Address soon - your appliance may not work properly

Also displayed as: tE1

How to Fix

  1. 1

    Enter diagnostic test mode by pressing POWER while pressing MORE TIME and LESS TIME simultaneously.

  2. 2

    Press START/PAUSE once to initiate the thermistor test step.

  3. 3

    Observe if tE1 is displayed — this indicates outlet thermistor open circuit.

  4. 4

    Turn power off and discharge voltage before measuring resistance.

  5. 5

    Disconnect the NA6 6-pin connector from the main PCB.

  6. 6

    Short Pin 3 (Yellow Wire) and Pin 4 (Blue Wire) on the NA6 connector using a metal wire or jumper.

  7. 7

    If controller now reads correctly, the thermistor harness or thermistor itself is faulty.

  8. 8

    Remove the jumper and measure resistance between thermistor terminals with harness disconnected.

  9. 9

    Compare measured resistance to Table 1: 50°F(10°C)=18.0kΩ, 60°F(16°C)=14.2kΩ, 70°F(27°C)=9.3kΩ, 80°F(21°C)=11.7kΩ, 90°F(32°C)=7.7kΩ, 100°F(38°C)=6.2kΩ, 110°F(43°C)=5.2kΩ, 120°F(49°C)=4.3kΩ, 130°F(54°C)=2.9kΩ, 140°F(60°C)=3.0kΩ, 150°F(66°C)=2.5kΩ, 160°F(71°C)=2.2kΩ.

  10. 10

    If resistance is out of range: replace the thermistor.

  11. 11

    If resistance is within range: check the harness-linking connector for damage or poor contact.

  12. 12

    If harness is good and jumper test passed: replace the main PCB controller.

This Error Applies To

LG DLEX3570V Series Dryers

Service manual exact match: DLEX3370WService manual exact match: DLGX3371VService manual exact match: DLEX3570VService manual exact match: DLEX3370RService manual exact match: DLGX3371WService manual exact match: DLEX3570WService manual exact match: DLGX3571VService manual exact match: DLGX3371R+2 more