Error Code InS
Installation test / Duct Check mode activated successfully
Moderate
Address soon - your appliance may not work properly
Also displayed as: InS
How to Fix
- 1
Step 1: Remove drying rack and literature; close door with nothing in drum
- 2
Step 2 (DLEX4200/DLEX4000/DLGX4201/DLGX4001): Press and hold Signal + Temp buttons simultaneously, then press Power button - InS confirms activation
- 3
Step 2 (DLE3600/DLG3601): Press and hold Wrinkle Care + Temp buttons, then press Power button - In confirms activation
- 4
Step 3: Press START/PAUSE - dryer runs test cycle (few minutes); heat turns on; drum temperature measured
- 5
Step 4: Monitor Flow Sense LED - if LED does not turn on when cycle ends, exhaust system is adequate
- 6
Step 5: If Flow Sense LED turns on, exhaust is severely restricted - service exhaust system immediately
- 7
Step 6: End displays at end of test; dryer shuts off automatically after short delay
This Error Applies To
LG DLEX4200W Series Dryers (2020) (2020–present)
Related Error Codes
Ductwork approximately 80% blocked — flow sense restriction warning
NFC module open or shorted
Big load indicator for steam cycle load size selection (not a fault code)
Thermistor of steam generator open or shorted
Power failure — circuit breaker tripped or power outage occurred
No power / power cord not connected correctly
Ductwork approximately 95% blocked — critical flow sense restriction
Thermistor of blower housing — outlet thermistor open or shorted