Error Code E5
Water supply pump AD value below 10 in test mode
Moderate
Address soon - your appliance may not work properly
Also displayed as: E5
How to Fix
- 1
Enter diagnostic test mode.
- 2
Press START/PAUSE button 4 times to reach pump test step; allow each step to complete before advancing.
- 3
Check the AD value displayed; if greater than 10, pump is normal.
- 4
If AD value is 10 or less, E5 is displayed.
- 5
Check harness connection between harness wire and pump connector for loose or damaged pins.
- 6
If harness is secure, replace the water supply pump (DC pump).
- 7
Retest in diagnostic mode to confirm E5 is cleared.
This Error Applies To
LG DLEX4370V Series Dryers