Error Code nP
No power detected
Moderate
Address soon - your appliance may not work properly
Also displayed as: nP
How to Fix
- 1
Check that dryer is plugged in and outlet has 110–125VAC.
- 2
Measure voltage between connectors BK2 or WH2 (Black Wire) and BL2 (White Wire) linked to controller; should be 110–125VAC.
- 3
If no voltage, check power cord connection.
- 4
If voltage is present but display remains off, check controller wire for disconnection and reconnect controller.
- 5
Verify power cord N (Neutral) line matches terminal center N line.
- 6
If all connections are correct and display remains off, replace the controller (main PCB).
This Error Applies To
LG DLEX4370V Series Dryers
Related Error Codes
Ductwork approximately 90% blocked
Outlet thermistor open or shorted (second thermistor)
Power supply wire connection wrong or loose (electric dryer)
NFC module open or shorted
Ductwork approximately 80% blocked
Steam generator thermistor open or shorted
Power failure or incorrect power supply
NFC module wrong or unresponsive