Error Code tE1
Outlet thermistor open or shorted
Moderate
Address soon - your appliance may not work properly
Also displayed as: tE1
How to Fix
- 1
Turn off the dryer power.
- 2
Remove connector NA6 from the controller.
- 3
Short pin 2 (Blue Wire) and pin 3 (Orange Wire) with a metal jumper.
- 4
If tE1 clears, check that NA6 connector and 6-pin connector are securely connected to controller; if connection is good, replace controller.
- 5
If tE1 persists, measure resistance between thermistor terminals with harness disconnected; compare to Table 1 (50°F/10°C = 18.0kΩ, 70°F/27°C = 9.3kΩ, 100°F/38°C = 6.2kΩ, 130°F/54°C = 2.9kΩ, 160°F/71°C = 2.2kΩ).
- 6
If resistance is out of range, replace thermistor.
- 7
If resistance is in range, check harness linking connector for corrosion, bent pins, or broken wires and repair as needed.
This Error Applies To
LG DLEX4370V Series Dryers
Related Error Codes
Outlet thermistor open or shorted (second thermistor)
Power supply wire connection wrong or loose (electric dryer)
NFC module open or shorted
Ductwork approximately 80% blocked
Steam generator thermistor open or shorted
Power failure or incorrect power supply
NFC module wrong or unresponsive
Ductwork approximately 90% blocked