LG Dryers2016–present

Error Code tE1

Thermistor of blower housing open or shorted

Moderate

Address soon - your appliance may not work properly

What This Means

Thermistor open circuit; Thermistor short circuit; Harness connection to NA6 connector loose or disconnected

How to Fix

  1. 1

    Turn off power and discharge voltage by contacting metal plug of power cord to ground

  2. 2

    Remove NA6 connector from controller

  3. 3

    Short Pin 1 (Blue Wire) and Pin 4 (Orange Wire) to controller — if short is detected, check control and 6-pin connector are properly connected, then replace controller

  4. 4

    If no short detected, measure resistance between thermistor assembly terminals after separating harness

  5. 5

    Compare measured resistance to temperature table (e.g., 50F=18kOhm, 70F=9.3kOhm, 90F=7.7kOhm)

  6. 6

    If resistance is out of range, replace thermistor

  7. 7

    If resistance is in range, check harness-linking connector