Error Code tE1
Thermistor fault — blower housing thermistor open or shorted
Moderate
Address soon - your appliance may not work properly
Also displayed as: tE1
How to Fix
- 1
Turn power off and discharge capacitors by contacting metal plug of power cord with ground.
- 2
Remove connector NA6 from the controller.
- 3
Short Pin 2 (Blue Wire) and Pin 5 (Orange Wire) on the NA6 connector to the controller.
- 4
If the error clears, check that the control connector and 6-pin harness are properly connected; replace controller if defective.
- 5
If error does not clear, measure resistance between thermistor assembly connector terminals after separating harness.
- 6
Compare measured resistance against Table 1: at 50°F (10°C) expect 18.0kΩ, 70°F (27°C) = 9.3kΩ, 100°F (38°C) = 6.2kΩ, 120°F (49°C) = 4.3kΩ, 140°F (60°C) = 3.0kΩ.
- 7
If resistance is out of range, replace the thermistor assembly.
- 8
If resistance is in range, inspect and repair harness-linking connector.
- 9
tE1 error is displayed during the drying cycle or in test mode.
This Error Applies To
LG DLEX7900VE Series Dryers
Related Error Codes
Steam generator thermistor open or shorted
Humidity sensor failure
Steam pump AD value below 10 — pump abnormal
Thermistor fault — blower housing thermistor open or shorted (alternate code)
EEPROM error — EEPROM operation is abnormal
FlowSense four-bar restriction detected — ductwork significantly restricted
Door switch abnormal — detected only in TEST MODE
Ductwork approximately 90% blocked — FlowSense alert