Error Code E5
Water supply pump error — pump AD value less than 10 in test mode
Moderate
Address soon - your appliance may not work properly
Also displayed as: E5
How to Fix
- 1
1. E5 error is only displayed in test mode.
- 2
2. Enter diagnostic mode and press START/PAUSE 4 times to activate pump test.
- 3
3. Allow dryer to complete each test step before proceeding — rapid pressing can damage main board.
- 4
4. Check display: If AD value of pump is higher than 10 → pump is normal.
- 5
5. If AD value is lower than 10 → E5 error will be displayed.
- 6
6. If E5 displayed → Check the connection between harness wire and connector at CN7.
- 7
7. If connections are OK → Replace the water supply pump (DC pump).
- 8
8. Also check CN7 connector pins 1-2 (Pump AG).
This Error Applies To
LG DLEX8900V Series Dryers
Related Error Codes
Steam generator thermistor open or shorted
Power failure / power supply error
Ductwork approximately 90% blocked — exhaust severely restricted
Power supply problem
Ductwork approximately 95% blocked — exhaust critically restricted
Outlet thermistor open or shorted (Thermistor of blower housing)
Steam feeder water supply error — steam generator not filled within 60 seconds
EEPROM / PCB memory error