Error Code PS
Wire connection wrong or loose (Black-White-Red power supply connections)
Moderate
Address soon - your appliance may not work properly
Also displayed as: PS
How to Fix
- 1
1. Verify proper connection of the power cord (electric dryer only). PS means power supply.
- 2
2. Check the power supply or the connection of power cord to the terminal block.
- 3
3. Refer to the Connecting Electric Dryers section for complete instructions.
- 4
4. Check voltage at main PCB between Black wire on blue tab relay connector (X562) and White wire on black tab relay connector (X4) — Is 120VAC present while pressing start?
- 5
5. If YES → Replace main PCB and/or display PCB.
- 6
6. If NO → Check voltage at terminal block between neutral (WH) and L1 (BK). Is voltage 120VAC while pressing START/PAUSE?
- 7
7. If NO → Check power cord; check terminal block connections.
- 8
8. If YES → Check voltage at power cord plug between neutral and L1 (and L2 for electric dryers). Is voltage 120VAC?
- 9
9. If NO → Check power supply fuse or circuit breaker; check receptacle connections.
- 10
10. If YES → Replace the power cord.
This Error Applies To
LG DLEX8900V Series Dryers
Related Error Codes
Steam generator thermistor open or shorted
Power failure / power supply error
Ductwork approximately 90% blocked — exhaust severely restricted
Water supply pump error — pump AD value less than 10 in test mode
Power supply problem
Ductwork approximately 95% blocked — exhaust critically restricted
Outlet thermistor open or shorted (Thermistor of blower housing)
Steam feeder water supply error — steam generator not filled within 60 seconds