Error Code tE1
Outlet thermistor open or shorted (Thermistor of blower housing)
Moderate
Address soon - your appliance may not work properly
Also displayed as: tE1
How to Fix
- 1
1. Turn off the dryer and call for service.
- 2
2. Enter diagnostic mode: unit in standby, press POWER while pressing MORE TIME and LESS TIME simultaneously, then press START/PAUSE.
- 3
3. Check if tE1 is displayed — indicates thermistor open condition.
- 4
4. Take NA8 connector from the controller. Measure resistance between NA8-pin3 (BL) and NA8-pin2 (YL).
- 5
5. Compare resistance to temperature chart: 50°F(10°C)=18.0kΩ, 60°F(16°C)=14.2kΩ, 70°F(27°C)=9.3kΩ, 80°F(21°C)=11.7kΩ, 90°F(32°C)=7.7kΩ, 100°F(38°C)=6.2kΩ, 110°F(43°C)=5.2kΩ, 120°F(49°C)=4.3kΩ, 130°F(54°C)=2.9kΩ, 140°F(60°C)=3.0kΩ, 150°F(66°C)=2.5kΩ, 160°F(71°C)=2.2kΩ.
- 6
6. If resistance does NOT match chart → go to step 7. If it DOES match → Check if control and 8-pin connector are properly connected; if yes, replace controller.
- 7
7. Separate harness from thermistor assembly connector. Check resistance in range of Table 1.
- 8
8. If resistance is NOT in range → Replace thermistor.
- 9
9. If resistance IS in range → Check harness-linking connector.
- 10
10. Also note: tE1 error displayed — replace the steam generator assembly if associated with steam function.
This Error Applies To
LG DLEX8900V Series Dryers
Related Error Codes
Steam generator thermistor open or shorted
Power failure / power supply error
Ductwork approximately 90% blocked — exhaust severely restricted
Water supply pump error — pump AD value less than 10 in test mode
Power supply problem
Ductwork approximately 95% blocked — exhaust critically restricted
Steam feeder water supply error — steam generator not filled within 60 seconds
EEPROM / PCB memory error