Error Code tE4
Steam generator thermistor open or shorted
Moderate
Address soon - your appliance may not work properly
Also displayed as: tE4
How to Fix
- 1
1. tE4 is displayed only in test mode.
- 2
2. In diagnostic test mode, press START/PAUSE button — tE4 indicates AG thermistor open or shorted.
- 3
3. Turn off dryer and discharge voltage.
- 4
4. Disconnect CN7 connector (Natural White) from main PCB — CN7 carries pins 1-2 Pump (AG), 3-5 AG Sensor H, 4-5 AG Thermistor.
- 5
5. Check resistance of AG thermistor pins at CN7.
- 6
6. Test generator assembly (Test 9): Is resistance 14.3Ω ± 5% between heater terminal 1 and 2?
- 7
7. If NO → Replace generator assembly / steam generator assembly.
- 8
8. If YES → Normal condition — check harness and connectors.
- 9
9. Replace the steam generator assembly.
This Error Applies To
LG DLEX8900V Series Dryers
Related Error Codes
Power failure / power supply error
Ductwork approximately 90% blocked — exhaust severely restricted
Water supply pump error — pump AD value less than 10 in test mode
Power supply problem
Ductwork approximately 95% blocked — exhaust critically restricted
Outlet thermistor open or shorted (Thermistor of blower housing)
Steam feeder water supply error — steam generator not filled within 60 seconds
EEPROM / PCB memory error