Error Code PF
Power cord incorrectly connected or power supply error (not 240V — may be 120V only)
Moderate
Address soon - your appliance may not work properly
Also displayed as: PF
How to Fix
- 1
Check that power cord is properly connected to terminal block (refer to pages 23-26)
- 2
Verify supply voltage: unit requires 208V or 240V AC; do NOT connect to 110V, 115V, or 120V single-phase — check with multimeter at terminal block
- 3
Verify circuit is fused at 30A on both sides of line
- 4
If voltage is correct and wiring is proper but error persists, replace power cord
This Error Applies To
LG DLHC1455 Series Dryers (2020) (2020–present)
Related Error Codes
Restricted motor — motor fails to start after restart attempts
Wi-Fi module communication error — Wi-Fi module single product fault
Wi-Fi product not registered (normal behavior until registered) or Wi-Fi module error
Compressor discharge pipe thermistor open or short circuit
Drum outlet thermistor open or short circuit
Compressor error — inverter compressor fault after restart attempts
Drum outlet thermistor open or short circuit
Door open detected during operation — machine restarts then stops