LG Dryers2020–present

Error Code tE

Drum outlet thermistor open or short circuit

Moderate

Address soon - your appliance may not work properly

Also displayed as: tE

How to Fix

  1. 1

    Check thermistor connector at main PCB (refer to PCB layout page 54) — verify connector is fully seated and not damaged

  2. 2

    Measure thermistor resistance terminal-to-terminal: normal value is 10 kΩ ±5% at 25°C; replace thermistor if out of range (R code: B139)

  3. 3

    If connector and thermistor are good, inspect and replace wire harness (R code: A190)

  4. 4

    If harness is good, replace main PCB (R code: A160)

This Error Applies To

LG DLHC1455 Series Dryers (2020) (2020–present)

Service manual exact match: DLHC1455VService manual exact match: DLHC1455W

Need more help with your LG dryers?