Error Code E CO
Communication Error — Main MICOM and Display MICOM
Moderate
Address soon - your appliance may not work properly
How to Fix
- 1
Check CON101 pin 1 to pin 2 voltage. Expected: 12 V. If not 12 V, check hinge connection for looseness. If hinge is OK, replace the Main PCB.
- 2
Check CON101 pin 5 to pin 2 voltage. Expected: 12 V. If not 12 V, check hinge for loose connection. If hinge is OK, replace the Main PCB.
- 3
Check CON101 pin 3 to pin 2 voltage. Expected: not 0 or 5 V. If 0 or 5 V, replace the Display PCB.
- 4
Check CON101 pin 4 to pin 2 voltage. Expected: not 0 or 5 V. If 0 or 5 V, replace the Main PCB.
- 5
Check CON5 pin 4 to pin 3 voltage. Expected: not 0 or 5 V. If 0 or 5 V, replace the Display PCB.
- 6
Check CON5 pin 5 to pin 3 voltage. Expected: not 0 or 5 V. If 0 or 5 V, replace the Main PCB.
- 7
If all voltages are correct, explain normal operation to customer.
This Error Applies To
LG LF29H8330 Series Refrigerators