LG Refrigerators

Error Code E Sd

Sub PCB Communication Error — Main MICOM and Sub MICOM

Moderate

Address soon - your appliance may not work properly

How to Fix

  1. 1

    Check all loose connections between Main PCB and Sub PCB. Reconnect any loose connectors.

  2. 2

    Measure voltage at Sub CON1 pins 8–33. Expected: not 0 or 5 V. If 0 or 5 V, check Sub PCB connection (possible loose connector) and replace Sub PCB if connection is secure.

  3. 3

    Measure voltage at Sub CON1 pins 10–33. Expected: not 0 or 5 V. If 0 or 5 V, check Sub PCB connection and replace Sub PCB if needed.

  4. 4

    Measure voltage at Main CON3 pins 1–15. Expected: not 0 or 5 V. If 0 or 5 V, check Display PCB connection (loose connector) and replace Display PCB if connection is secure.

  5. 5

    Measure voltage at Main CON3 pins 3–15. Expected: not 0 or 5 V. If 0 or 5 V, check Display PCB connection and replace Display PCB if needed.

  6. 6

    If all voltages are correct, explain normal operation to customer.

This Error Applies To

LG LF29H8330 Series Refrigerators

Service manual exact match: LF29H8330SService manual exact match: LF29H8330BService manual exact match: LF29H8330W

Need more help with your LG refrigerators?