Error Code E Sd
Sub PCB Communication Error — Main MICOM to Sub MICOM
Moderate
Address soon - your appliance may not work properly
How to Fix
- 1
Check all connectors between main PCB and sub PCB for loose or disconnected wiring. Reconnect as needed.
- 2
Measure voltage at Sub CON1 8th Pin to 33rd Pin. Expected: not 0 or 5 V (oscillating). If static 0 or 5, check Sub PCB connection — replace Sub PCB if connection is good.
- 3
Measure voltage at Sub CON1 10th Pin to 33rd Pin. Expected: not 0 or 5 V. If static, check Sub PCB connection — replace Sub PCB if connection is good.
- 4
Measure voltage at Main CON3 1st Pin to 15th Pin. Expected: not 0 or 5 V. If static, check Display PCB connection — replace Display PCB if connection is good.
- 5
Measure voltage at Main CON3 3rd Pin to 15th Pin. Expected: not 0 or 5 V. If static, check Display PCB connection — replace Display PCB if connection is good.
- 6
If all checks pass, explain normal operation to customer.
This Error Applies To
LG LF29H8330D Series Refrigerators