Error Code E CS
Convertible room sensor error (pantry sensor error)
Moderate
Address soon - your appliance may not work properly
Also displayed as: E CS
How to Fix
- 1
Check if connector between Main PCB and convertible sensor is loose or disconnected; if yes, reconnect or repair and retest.
- 2
With power OFF, measure resistance at CON8 18th Pin to 17th Pin. If resistance is 0 Ohm (short circuit), replace the convertible room sensor.
- 3
If resistance is open/infinite (OL), go to step 6.
- 4
If resistance reads a value, compare against the temperature-resistance table for current temperature. If mismatch, replace the sensor.
- 5
If resistance matches expected value, explain normal operation to customer.
- 6
Check the sensor connection harness. If the connection is normal, replace the refrigerator main PCB.
This Error Applies To
LG LF29S8330 Series Refrigerators