Error Code F dH
Defrosting failure — defrost sensor did not reach 41°F (5°C) within 80 minutes
Moderate
Address soon - your appliance may not work properly
How to Fix
- 1
Inspect door gasket for damage or gaps. If damaged, replace door gasket.
- 2
With power off, measure defrost heater resistance at CON9 pins 5-13 (TEST MODE 1). Expected: 42-50 ohm (combined). If heater resistance is not 42-50 ohm, check Fuse-M continuity (should be 0-0.1 ohm); if Fuse-M is open, replace Fuse-M.
- 3
Individual heater resistances: Sheath heater (1) = 62-70 ohm; Defrost heater (2) = 144-167 ohm. Measure each individually if combined reading is wrong.
- 4
Measure defrost sensor (FD-SNR) resistance at CON8 pins 26-25. Expected ~22k at room temp per table. If open or wildly out of range, replace defrost sensor.
- 5
Enter TEST MODE 3 (press test button 3 times) to force defrost. Check heater voltage at CON9 pins 5-13. Expected: 112V-116V AC. If voltage is not present, replace main PCB.
- 6
Enter TEST MODE 1 (press test button 1 time). Check heater voltage at CON9 pins 5-13. Expected: 0V (heater off in compressor mode). If voltage is not 0V, replace main PCB.
- 7
If heater voltage is correct in both modes and heater/fuse resistance is correct, check drain tube for blockage and clear it.
This Error Applies To
LG LF30S8210S Series Refrigerators
Related Error Codes
Convertible Sensor Error (Pantry/Full-Convert Drawer sensor)
Defect of freezer sensor
Defect of refrigerator sensor
Defect of freezer defrosting sensor
Defect of room temperature sensor
Defect of humidity sensor
Defect of ice maker sensor
Malfunction of ice maker motor (ice maker kit defect)