LG Refrigerators

Error Code E CO

Communication error between main MICOM and display MICOM

Moderate

Address soon - your appliance may not work properly

How to Fix

  1. 1

    Check all connector housings at CON101 (hinge connector between main and display PCB) and CON5 for looseness.

  2. 2

    Measure voltage at CON101 pins 1-2. Expected: 12V DC. If not 12V, check hinge wiring for looseness or damage; if wiring is good, replace main PCB.

  3. 3

    Measure voltage at CON101 pins 5-2. Expected: 12V DC. If not 12V, check hinge wiring; if good, replace main PCB.

  4. 4

    Measure voltage at CON101 pins 3-2. Expected: Not 0V or 5V (active signal). If stuck at 0V or 5V, replace display PCB.

  5. 5

    Measure voltage at CON101 pins 4-2. Expected: Not 0V or 5V. If stuck, replace main PCB.

  6. 6

    Measure voltage at CON5 pins 4-3. Expected: Not 0V or 5V. If stuck, replace display PCB.

  7. 7

    Measure voltage at CON5 pins 5-3. Expected: Not 0V or 5V. If stuck, replace main PCB.

  8. 8

    If all signals are correct, explain to customer.

This Error Applies To

LG LF30S8210S Series Refrigerators

Service manual exact match: LF30S8210S