LG Refrigerators

Error Code E gF

Defect of flow meter — malfunction of flow meter or lack of water supply

Moderate

Address soon - your appliance may not work properly

Also displayed as: E gF

How to Fix

  1. 1

    Step 1: Check flow meter connector connection and water supply line at shutoff valve.

  2. 2

    Step 2: Verify water supply is turned on and line pressure is adequate.

  3. 3

    Step 3: Measure flow sensor resistance — red wire to black wire should be 4~30 kOhms. If out of range, replace flow sensor.

  4. 4

    Step 4: Inspect water filter; replace if clogged or overdue (every 6 months).

  5. 5

    Step 5: Check for kinked or frozen water supply tubing.

This Error Applies To

LG LF31S6360 Series Refrigerators

Service manual exact match: LF31S6360SService manual exact match: LF31S6360BService manual exact match: LF31S6360WService manual exact match: LF31S6360D

Need more help with your LG refrigerators?