LG Refrigerators
Error Code dS E
Defrost Sensor Error
Moderate
Address soon - your appliance may not work properly
Also displayed as: dS E
How to Fix
- 1
Check for a loose connection at CON7 from Main PCB.
- 2
Unplug connector from CON7.
- 3
Measure resistance between Brown and Brown wires (Drawer Model), or Orange to Orange (Swing Model).
- 4
If 0 ohm (short): Replace the defrost sensor.
- 5
If open (infinite/OL): Replace the refrigerator control board (Main PCB).
- 6
If within range, verify against Temperature Table-3: 23F(-5C)=38.5-36.5kΩ, 32F(0C)=30.5-29.5kΩ, 41F(5C)=24.5-23.5kΩ, 50F(10C)=20-19kΩ, 59F(15C)=16-15.5kΩ.
- 7
If resistance is normal for ambient temperature, check wiring harness for intermittent opens.
This Error Applies To
LG LFCS22520B Series Refrigerators
Service manual exact match: LFCS22520BService manual exact match: LFCS22520SService manual exact match: LFCS22520WService manual exact match: LFNS22520S