How to Fix

  1. 1

    Step 1: Check all connector connections for looseness. Check hinge area for harness pinching.

  2. 2

    Step 2: Check voltage in display at CON101 16th~18th pin. Expected: 11.5~12.5V. If not, change the Main PCB.

  3. 3

    Step 3: Check voltage in display at CON101 16th~10th pin. Expected: 5~7.5V.

  4. 4

    Step 4: Check voltage in display at CON101 16th~14th pin. Expected: Not 0V or 5V (should be pulsing). If 0V or 5V, change the Display PCB.

  5. 5

    Step 5: Check voltage in display at CON101 16th~12th pin. Expected: Not 0V or 5V. If 0V or 5V, change the Main PCB.

  6. 6

    Step 6: Check voltage in Main PCB at CON5 15th~17th pin. Expected: Not 0V or 5V. If 0V or 5V, change the Display PCB.

  7. 7

    Step 7: Check voltage in Main PCB at CON5 15th~18th pin. Expected: Not 0V or 5V. If 0V or 5V, change the Main PCB.

  8. 8

    Step 8: If all checks pass, explain to customer.