Error Code E UC
UV/Nano LED Module Error — Bad UV LED module or poor connection between display and UV module. Caused when feedback signals are abnormal.
Moderate
Address soon - your appliance may not work properly
Also displayed as: E UC
How to Fix
- 1
Step 1: Check connection between display PCB and UV LED module for loose or disconnected harness.
- 2
Step 2: Inspect UV LED module for physical damage.
- 3
Step 3: If harness is secure and module appears normal, replace the UV LED module.
- 4
Step 4: If replacement does not resolve, replace the display PCB.
This Error Applies To
LG LHSXS2706 Series Refrigerators
Related Error Codes
Freezer Sensor Error — Freezer sensor short or open
Refrigerator Sensor Error — Refrigerator sensor (upper part) short or open
Defrost Sensor Error — Defrost sensor short or open
Failed Defrosting — Defrost heater, temperature fuse short circuited or unplugged connector. Error indicated 4 hours after failure occurs.
Abnormal Freezer Fan Motor — Connection line of fan motor is fault, short, or open. Fault displayed when operating fan motor for 65 seconds without output signal.
Condenser Fan Motor Error — Connection line of condenser fan motor is fault, short, or open. Fault displayed when operating fan motor for 65 seconds without output signal.
Abnormal Communication Error — Connection line between main control panel and display panel is short or open. Signal transmission fails.
Abnormal Ambient (Room) Temperature Sensor Error — Room temperature sensor short or open.