LG Refrigerators

Error Code E lU

Abnormal Craft Ice Maker Unit — Craft ice maker step motor fault or Hall IC/wire short. Fault motor driving circuit.

Moderate

Address soon - your appliance may not work properly

Also displayed as: E lU

How to Fix

  1. 1

    Step 1: Check connector between Main PCB and craft ice maker for looseness.

  2. 2

    Step 2: If disconnected, reconnect or repair the connector.

  3. 3

    Step 3: Check craft ice maker motor resistance at CON3 26th~28th pin. Expected: 19.7 ohm. If incorrect, replace the craft ice maker (VM) unit.

  4. 4

    Step 4: Push I/M test key and test voltage at CON3 23rd~25th pin. Expected: 0~5V varying. If incorrect, change IM unit or replace Main PCB.

  5. 5

    Step 5: Check craft ice heater resistance: Upper HTR (Red) 14.1~16.3 ohm, Lower HTR (White) 14.1~16.3 ohm. Replace if out of range.

  6. 6

    Step 6: If all values are correct, explain to customer.

This Error Applies To

LG LHSXS2706 Series Refrigerators

Service manual exact match: LHSXS2706SService manual exact match: LHSXS2706VService manual exact match: LHSXS2706DService manual exact match: LHSXS2706W