LG Refrigerators2017–present

Error Code CO E

Communication Error between Main PCB and Display Micom

Moderate

Address soon - your appliance may not work properly

Also displayed as: CO E

What This Means

Poor communication connection; Poor transistor (TR) on transmitter/receiver; Loose hinge connection; Loose CON101 or CON5 connector

How to Fix

  1. 1

    Check all connectors (CON101, CON5) for loose connections. Reconnect if loose.

  2. 2

    Measure voltage at CON101 7th pin to 6th pin. Should be 12V. If not 12V, check hinge connections for loose contact then replace Main PCB if hinge is OK.

  3. 3

    Measure voltage at CON101 3rd pin to 6th pin. Should be 5V. If not 5V, replace Main PCB.

  4. 4

    Measure voltage at CON101 5th pin to 6th pin. Should be varying (not fixed 0V or 5V). If fixed 0V or 5V, replace Display PCB.

  5. 5

    Measure voltage at CON101 4th pin to 6th pin. Should be varying (not fixed 0V or 5V). If fixed 0V or 5V, replace Main PCB.

  6. 6

    Measure voltage at CON5 4th pin to 6th pin. Should be varying. If fixed, replace Display PCB.

  7. 7

    Measure voltage at CON5 4th pin to 8th pin. Should be varying. If fixed, replace Main PCB.

  8. 8

    If all voltages check out, explain normal operation to customer.

This Error Applies To

LG LMXS28626S Series Refrigerators (2017) (2017–present)

Service manual exact match: LMXS28626SService manual exact match: LMXS28626DService manual exact match: LMXS28626WService manual exact match: LMXS28626BService manual exact match: LFXS28566SService manual exact match: LFXS28566DService manual exact match: LFXS28566WService manual exact match: LFXS28566B+2 more

Need more help with your LG refrigerators?