Error Code E CL
Low Side Cycle Leakage (refrigerant leak or sealed system restriction on low side)
Moderate
Address soon - your appliance may not work properly
What This Means
Low side refrigerant leak; Restriction in sealed system (low side); Bad compressor; Long-duration door open; Evaporator or suction pipe leak
How to Fix
- 1
Check display for E CL error code
- 2
Use SVC App or temperature gun to determine compressor vs sealed system fault
- 3
Check voltage to confirm PCB operation
- 4
Measure equilibration pressure on high and low pressure parts (drier and comp processing pipe)
- 5
If slow equalization (15+ min): clogging confirmed
- 6
Check equalized pressure to determine if refrigerant is sufficient
- 7
If leak: perform leak test using refrigerant or nitrogen
- 8
Check low-pressure parts: Evaporator, Suction pipe, etc.
- 9
If no low-side leak: check high-pressure parts (Condenser, Drier)
- 10
After sealed system repair: error disappears automatically when freezer reaches 14F; use UV drier on next visit
This Error Applies To
LG LRDCS2603S Series Refrigerators (2020) (2020–present)
Related Error Codes
Freezer Fan Error (BLDC Fan Motor for Freezer)
Refrigerator Sensor Error
Icing Sensor Error (Ice Maker sensor)
Freezer Defrost Sensor Error
Freezer Sensor Error
Freezer Defrost Heater Error — defrost sensor has not reached 41F/5C within 80 minutes of defrost start
Communication Error between Main PCB MICOM and Display MICOM
Room Temperature Sensor Error