LG Refrigerators2020–present

Error Code E FF

Freezer Fan Error (BLDC Fan Motor for Freezer)

Moderate

Address soon - your appliance may not work properly

What This Means

Freezer fan motor mechanically seized (ice or rust inside motor bearing); Loss of feedback signal from BLDC fan motor within 65 seconds of operation; Poor BLDC motor connection, DRIVE IC, or TR on PCB

How to Fix

  1. 1

    Reset unit and input Test Mode 1 by pressing test button once (display shows -00 00)

  2. 2

    Open freezer door and check for airflow at fan outlet; note: fan does not run while error is displayed

  3. 3

    If no airflow: check fan motor — rotate fan blade by hand; if sticky/stiff, replace motor (ice or rust in bearing)

  4. 4

    If airflow present: check for loose connection at CON7

  5. 5

    Measure fan motor voltage at CON7: pins 12-14: below 10V = change PCB; pins 14-16: 0 or 5V = change PCB; pins 12-14 signal: 0 or 5V = change motor

  6. 6

    Fan motor wiring: PR pin 10, BO/BL pin 12, BO pin 14, GY/RD pin 16 at CON7