Error Code F dH
Freezer Defrost Heater Error — defrost sensor has not reached 41F/5C within 80 minutes of defrost start
Moderate
Address soon - your appliance may not work properly
What This Means
Failed door gasket (air infiltration causes frost buildup requiring extended defrost); Open or failed Fuse-M (thermal fuse); Open or failed defrost heater (sheath heater); Failed defrost sensor reading below spec; Main PCB not supplying voltage to heater
How to Fix
- 1
Check the door gasket for damage or poor seal
- 2
Check loose connection in defrost control part connector
- 3
Measure resistance of Fuse-M (pins 1-2): normal = 0-0.1 Ohm; if infinite = disconnected, replace Fuse-M
- 4
Measure resistance of defrost heater (sheath heater): normal = 34-42 Ohm; if other = change Fuse-M
- 5
Measure resistance of defrost sensor: normal = approx 21 Ohm at operating temp; if other = go to step 5
- 6
Enter Test Mode 3 by pressing test button 3 times (display shows 33 33)
- 7
Check for loose connection at CON3
- 8
Check voltage between Brown to A (line) wires at CON3: 112-116V = go to step 5; 0V = replace Main PCB
- 9
Release test mode by pressing button once (display returns to normal)
- 10
Check voltage between Brown to A at CON3 again: 0V = explain to customer (normal, heater not energized outside defrost); 112-116V = replace Main PCB
This Error Applies To
LG LRDCS2603S Series Refrigerators (2020) (2020–present)
Related Error Codes
Freezer Fan Error (BLDC Fan Motor for Freezer)
Refrigerator Sensor Error
Icing Sensor Error (Ice Maker sensor)
Freezer Defrost Sensor Error
Freezer Sensor Error
Communication Error between Main PCB MICOM and Display MICOM
Low Side Cycle Leakage (refrigerant leak or sealed system restriction on low side)
Room Temperature Sensor Error