What This Means

Poor communication connection between Main PCB and Display PCB; Loose hinge wiring connection

How to Fix

  1. 1

    Step 1: Check all connector hinge connections between Main PCB and Display PCB.

  2. 2

    Step 2: Measure voltage at CON101 pins 18-16 — expected 12V; if absent, check hinge connection (loose) and if connection is good, replace Main PCB.

  3. 3

    Step 3: Measure voltage at CON101 pins 10-16 — expected 5V; if absent, check hinge connection and if good, replace Main PCB.

  4. 4

    Step 4: Measure voltage at CON101 pins 14-16 — expected NOT 0 or 5V; if 0 or 5V, replace Display PCB.

  5. 5

    Step 5: Measure voltage at CON101 pins 12-16 — expected NOT 0 or 5V; if 0 or 5V, replace Main PCB.

  6. 6

    Step 6: Measure voltage at CON5 pins 4-3 — expected NOT 0 or 5V; if 0 or 5V, replace Display PCB.

  7. 7

    Step 7: Measure voltage at CON5 pins 5-3 — expected NOT 0 or 5V; if 0 or 5V, replace Main PCB.

  8. 8

    Step 8: If all checks are normal, explain to customer.