LG Refrigerators2023–present

Error Code E Sd

Sub PCB Communication Error — Main MICOM and Sub MICOM

Moderate

Address soon - your appliance may not work properly

What This Means

Defective Tx or Rx communication line; Defective Sub PCB; Loose connector between Main PCB and Sub PCB

How to Fix

  1. 1

    Step 1: Check all loose connections between Main PCB and Sub PCB.

  2. 2

    Step 2: Measure voltage at Sub CON1 pins 8-33 — expected NOT 0 or 5V; if 0 or 5V, check Sub PCB connection and if normal, replace Sub PCB.

  3. 3

    Step 3: Measure voltage at Sub CON1 pins 10-33 — expected NOT 0 or 5V; if 0 or 5V, check Sub PCB connection and replace Sub PCB.

  4. 4

    Step 4: Measure voltage at Main CON3 pins 1-15 — expected NOT 0 or 5V; if 0 or 5V, check Display PCB loose connection and replace Display PCB.

  5. 5

    Step 5: Measure voltage at Main CON3 pins 3-15 — expected NOT 0 or 5V; if 0 or 5V, check Display PCB loose connection and replace Display PCB.

  6. 6

    Step 6: If all checks are normal, explain to customer.

This Error Applies To

LG LRFOC2606 Series Refrigerators (2023) (2023–present)

Service manual exact match: LRFOC2606VService manual exact match: LRFOC2606DService manual exact match: LRFOC2606S