LG Refrigerators

Error Code E CL

Low Side Cycle Leakage — Sealed System Problem

Moderate

Address soon - your appliance may not work properly

Also displayed as: CL E

How to Fix

  1. 1

    Use SVC App Step 1 to determine if this is a sealed system problem or a customer usage issue.

  2. 2

    Check PCB output voltage to rule out PCB failure. Replace PCB if defective.

  3. 3

    Measure time for pressure equalization after power off. Over 15 minutes equalization time indicates restriction.

  4. 4

    If equalization pressure is above 40 psi, suspect bad compressor. Replace compressor.

  5. 5

    If equalization pressure is 40 psi or less, refrigerant has leaked.

  6. 6

    Check low pressure side parts (evaporator, suction pipe) for leaks first.

  7. 7

    If no low side leak found, check high pressure side parts (condenser, drier).

  8. 8

    If leak on low pressure side found, replace the leaking part, the drier, AND the compressor (moisture may have entered the low pressure system).

  9. 9

    After repair, wait until freezer reaches 14F — error code clears automatically.

  10. 10

    If temperature is normal and E CL still shows, use forced deletion: press F key + R key 3 times with door open.

  11. 11

    Install UV drier for next visit to confirm no further leaks.

This Error Applies To

LG LRMDS3006D Series Refrigerators

Service manual exact match: LRMDS3006DService manual exact match: LRMDS3006SService manual exact match: LRMVS3006DService manual exact match: LRMVS3006S

Need more help with your LG refrigerators?