Error Code E CO
Communication Error between Main PCB and Display PCB
Moderate
Address soon - your appliance may not work properly
Also displayed as: co E
How to Fix
- 1
Check all loose connections between Main PCB and Display PCB via CON101 hinge connector.
- 2
Measure voltage at CON101 pins 5-4. Expected: 12V supply. If absent, check hinge wiring or loose connection; replace Main PCB if hinge OK.
- 3
Measure voltage at CON101 pins 1-4. Expected: 5V logic supply. If absent, check hinge or replace Main PCB.
- 4
Measure voltage at CON101 pins 2-4. Expected: not 0V or 5V (active data). If reads 0V or 5V, replace Display PCB.
- 5
Measure voltage at CON101 pins 3-4. Expected: not 0V or 5V. If reads 0V or 5V, replace Main PCB.
- 6
Measure voltage at CON5 pins 12-11. Expected: not 0V or 5V. If reads 0V or 5V, replace Display PCB.
- 7
Measure voltage at CON5 pins 14-11. Expected: not 0V or 5V. If reads 0V or 5V, replace Main PCB.
- 8
Explain to customer if all checks pass.
This Error Applies To
LG LRMDS3006D Series Refrigerators
Related Error Codes
Freezer Sensor Error
Refrigerator Defrost Sensor Error
Freezer Defrost Heater Error — Freezer failed to defrost within 80 minutes
Refrigerator Defrost Heater Error — Refrigerator failed to defrost within 80 minutes
Freezer Fan Motor Error
Refrigerator Sensor Error
Icing Sensor Error (Ice Compartment Sensor or Ice Maker Sensor)
Freezer Defrost Sensor Error