LG Refrigerators2020–present

Error Code E CH

High-Side Cycle Leakage — detected by compressor high-side refrigerant leak, restriction, bad compressor, or bad 3-way valve

Moderate

Address soon - your appliance may not work properly

Also displayed as: E CH

How to Fix

  1. 1

    Note the error code and use the LG SVC App Step 1 to determine if the sealed system is at fault or if it is a customer/usage issue.

  2. 2

    If SVC App is not available, use a temperature gun to check evaporator temperature.

  3. 3

    Check PCB output voltage at CON201 to confirm Main PCB is not the cause.

  4. 4

    After power off, measure the time for high and low side pressures to equalize. If equalization takes more than 15 minutes, a restriction is present.

  5. 5

    If equalization pressure is 40 psi or more, the refrigerant charge is normal — the compressor is likely defective. Replace the compressor.

  6. 6

    If equalization pressure is below 40 psi, refrigerant has leaked. Perform leak test on high-pressure parts first: condenser, drier, compressor discharge pipe.

  7. 7

    If no high-side leak found, check low-pressure parts: evaporator, suction pipe.

  8. 8

    Replace leaking parts along with the drier after any sealed system repair.

  9. 9

    After repair, the error code clears automatically once freezer temperature drops to 14F or below (typically within 1 day).

  10. 10

    To force clear the error code: press F key + R key 3 times with door open.

  11. 11

    For follow-up visits, install a UV drier to locate future leaks.

This Error Applies To

LG LRMVS3006D Series Refrigerators (2020) (2020–present)

Service manual exact match: LRMVC2306SService manual exact match: LRMVC2306DService manual exact match: LRMDS3006DService manual exact match: LRMDS3006SService manual exact match: LRMVS3006DService manual exact match: LRMVS3006SService manual exact match: LRMDC2306SService manual exact match: LRMDC2306D