Error Code E CL
Low-Side Cycle Leakage — detected by low-side refrigerant leak, bad compressor, or prolonged door open
Moderate
Address soon - your appliance may not work properly
Also displayed as: E CL
How to Fix
- 1
Note the error code and use the LG SVC App Step 1 to determine sealed system fault vs. customer usage.
- 2
If SVC App is not available, use a temperature gun to check evaporator temperature.
- 3
Check PCB output voltage to confirm Main PCB is not the cause.
- 4
After power off, measure time for high and low side pressures to equalize. More than 15 minutes indicates restriction.
- 5
If equalization pressure is 40 psi or more, refrigerant is normally charged — compressor is likely defective. Replace compressor.
- 6
If equalization pressure is below 40 psi, refrigerant has leaked. Check low-pressure parts first: evaporator, suction pipe.
- 7
If no low-side leak found, check high-pressure parts: condenser, drier.
- 8
Because low-side leaks are below atmospheric pressure, moisture infiltration is likely. Replace both drier and compressor if low-side leak is found.
- 9
After repair, error code clears once freezer reaches 14F or below.
- 10
To force clear: press F key + R key 3 times with door open.
This Error Applies To
LG LRMVS3006D Series Refrigerators (2020) (2020–present)
Related Error Codes
Freezer Sensor Error — short or open circuit in the freezer thermistor
Refrigerator Sensor Error — short or open circuit in the fresh food compartment thermistor
Freezer Defrost Sensor Error — short or open circuit in the freezer defrost sensor
Refrigerator Defrost Sensor Error — short or open circuit in the refrigerator defrost sensor
Humidity Sensor Error — short or open circuit in the humidity sensor
Convertible (Pantry/Full Convert) Sensor Error — short or open circuit in the pantry drawer sensor
Room Temperature Sensor Error — short or open circuit in the ambient room temperature sensor
Icing Sensor Error — short or open circuit in the icing compartment (in-door icemaker) sensor