Error Code E CO
Communication Error — loss of communication between Main PCB Micom and Display PCB Micom
Moderate
Address soon - your appliance may not work properly
Also displayed as: E CO
How to Fix
- 1
Check all harness connections between Main PCB and Display PCB.
- 2
Measure voltage at CON101 pins 5~4. Expected 12V. If not 12V, check the hinge connection (loose) or replace Main PCB.
- 3
Measure voltage at CON101 pins 1~4. Expected 5V. If not 5V, check hinge connection (loose) or replace Main PCB.
- 4
Measure voltage at CON101 pins 2~4. If fixed at 0V or 5V (not variable), replace the Display PCB.
- 5
Measure voltage at CON101 pins 3~4. If fixed at 0V or 5V (not variable), replace the Main PCB.
- 6
Measure voltage at CON5 pins 12~11. If fixed at 0V or 5V, replace the Display PCB.
- 7
Measure voltage at CON5 pins 14~11. If fixed at 0V or 5V, replace the Main PCB.
- 8
If all voltage checks pass, explain normal operation to customer.
This Error Applies To
LG LRMVS3006D Series Refrigerators (2020) (2020–present)
Related Error Codes
Freezer Sensor Error — short or open circuit in the freezer thermistor
Refrigerator Sensor Error — short or open circuit in the fresh food compartment thermistor
Freezer Defrost Sensor Error — short or open circuit in the freezer defrost sensor
Refrigerator Defrost Sensor Error — short or open circuit in the refrigerator defrost sensor
Humidity Sensor Error — short or open circuit in the humidity sensor
Convertible (Pantry/Full Convert) Sensor Error — short or open circuit in the pantry drawer sensor
Room Temperature Sensor Error — short or open circuit in the ambient room temperature sensor
Icing Sensor Error — short or open circuit in the icing compartment (in-door icemaker) sensor