Error Code E gF
Flow Meter Sensor Error — defective flow meter, water motor error, or low water pressure
Moderate
Address soon - your appliance may not work properly
Also displayed as: E gF
How to Fix
- 1
Check for loose or disconnected connector at the flow meter.
- 2
Measure flow sensor resistance (red wire to black wire; expected 4~30 kohm).
- 3
If resistance is out of range, replace the flow sensor.
- 4
Check water supply pressure. Low water pressure can trigger this error.
- 5
Verify water filter is not clogged or overdue for replacement.
- 6
Check water valve connections and operation.
- 7
If sensor and water supply are normal, replace the main PCB.
This Error Applies To
LG LRMVS3006D Series Refrigerators (2020) (2020–present)
Related Error Codes
Freezer Sensor Error — short or open circuit in the freezer thermistor
Refrigerator Sensor Error — short or open circuit in the fresh food compartment thermistor
Freezer Defrost Sensor Error — short or open circuit in the freezer defrost sensor
Refrigerator Defrost Sensor Error — short or open circuit in the refrigerator defrost sensor
Humidity Sensor Error — short or open circuit in the humidity sensor
Convertible (Pantry/Full Convert) Sensor Error — short or open circuit in the pantry drawer sensor
Room Temperature Sensor Error — short or open circuit in the ambient room temperature sensor
Icing Sensor Error — short or open circuit in the icing compartment (in-door icemaker) sensor