How to Fix
- 1
Reset the unit and enter Test Mode 1 (press test button 1 time on Main PCB).
- 2
Open the freezer door and check air flow from the icing fan. If airflow is present (windy), go to step 4.
- 3
If no airflow, physically rotate the fan blade by hand. If blade feels sticky/seized, replace the icing fan motor.
- 4
Measure fan motor supply voltage at CON3 pins 24~21. Expected 11.4~12.6V.
- 5
If supply voltage is not 11.4~12.6V, replace the Main PCB.
- 6
If supply voltage is correct, measure fan feedback voltage at CON3 pins 22~21. If voltage reads 0V or 5V (fixed), replace the motor.
- 7
Measure fan PWM voltage at CON3 pins 23~21. If voltage reads 0V or 5V (fixed), replace the Main PCB.
- 8
If all voltages are normal and fan runs freely, explain normal operation to customer.
This Error Applies To
LG LRMVS3006D Series Refrigerators (2020) (2020–present)
Related Error Codes
Freezer Sensor Error — short or open circuit in the freezer thermistor
Refrigerator Sensor Error — short or open circuit in the fresh food compartment thermistor
Freezer Defrost Sensor Error — short or open circuit in the freezer defrost sensor
Refrigerator Defrost Sensor Error — short or open circuit in the refrigerator defrost sensor
Humidity Sensor Error — short or open circuit in the humidity sensor
Convertible (Pantry/Full Convert) Sensor Error — short or open circuit in the pantry drawer sensor
Room Temperature Sensor Error — short or open circuit in the ambient room temperature sensor
Icing Sensor Error — short or open circuit in the icing compartment (in-door icemaker) sensor