Error Code PE
Pressure Sensor Error - water level sensor malfunction
Moderate
Address soon - your appliance may not work properly
What This Means
Pressure sensor connector disconnected or disassembled; Pressure sensor resistance outside 21-23 Ohm range (pin 1 to pin 3, +/-10%); Air chamber and tube clogged
How to Fix
- 1
Confirm PE ERROR is displayed
- 2
Check connector to pressure sensor - if disconnected, reconnect or repair
- 3
Check resistance of pressure sensor (pin 1 to pin 3) - should be 21-23 Ohm +/-10%
- 4
If resistance out of range: replace the pressure switch
- 5
Check if AIR CHAMBER and tube are clogged - if yes, fix chamber and remove foreign material
- 6
If all above OK: replace MAIN PWB assembly
This Error Applies To
LG WM6700H Series Washers (2022) (2022–present)
Related Error Codes
Door Open Error - door not properly closed or locked
Unbalance Error - load is not evenly distributed in drum
Too much detergent causing excessive suds
ezDispense Softener Pump Error - softener injection pump failure
ezDispense Detergent Dispense Sensor Error
ezDispense Softener Dispense Sensor Error
ezDispense System Error - automatic detergent injection pump connector fault
Inlet Valve Error - water supply problem detected