Error Code FE
Overflow Error — water is overflowing; water level frequency is over 21.3 kHz. Note: when FE is displayed, the drain pump will operate automatically to drain water. Power will NOT be turned off automatically.
Moderate
Address soon - your appliance may not work properly
What This Means
Water overflowing — water level frequency over 21.3 kHz; Air chamber or tube clogged; Inlet valve open continuously when power is not applied (stuck open) — replace inlet valve; MAIN PWB ASSEMBLY driving inlet valve continuously
How to Fix
- 1
Confirm FE is displayed. Note: drain pump operates automatically; power stays on.
- 2
Press WASH/RINSE and DELAY WASH simultaneously; check if water level frequency is over 21.3 kHz. If NO → check air chamber and tube for clog.
- 3
If YES → check if inlet valve works (opens) when power is not applied. If YES → replace INLET VALVE ASSEMBLY.
- 4
If NO (valve does not open without power) → check if inlet valve is open continuously when power IS applied. If YES → replace MAIN PWB ASSEMBLY.
This Error Applies To
LG WM8100H Series Washers (2016) (2016–present)
Related Error Codes
Suds Error — too many suds detected. Machine adds a Suds Reducing cycle (adds approximately 2 hours to cycle time). If too many suds detected during spinning, machine stops to prevent leaking.
Pressure Sensor Error — PRESSURE SENSOR ASSEMBLY is out of order; water level frequency consistently below 10 kHz or over 30 kHz. Note: PE error will not disappear when START/PAUSE is pressed; if unresolved within 20 seconds power turns off and error blinks.
Locked Motor Error — motor or motor harness fault.
Unbalance Error — load balance issue prevents spin.
Door Open Error (variant) — door switch circuit fault, same root causes as dE1.
EEPROM Error — EEPROM is out of order. Displayed only when START/PAUSE button is first pressed in Load Test Mode.
Power Failure — power supply was interrupted while washing machine was in operation, then power was rapidly restored.
Water Inlet Error — correct water level (24.6 kHz) not reached within 8 minutes after water is supplied, or does not reach preset water level within 20 minutes.