Error Code PE

Pressure Sensor Error — PRESSURE SENSOR ASSEMBLY is out of order; water level frequency consistently below 10 kHz or over 30 kHz. Note: PE error will not disappear when START/PAUSE is pressed; if unresolved within 20 seconds power turns off and error blinks.

Moderate

Address soon - your appliance may not work properly

What This Means

Pressure sensor connector broken or loose; Pressure sensor resistance out of range (pin 1 to pin 3 should be 21-23 Ω ±10%); Air chamber or tube clogged with foreign material; MAIN PWB ASSEMBLY failure

How to Fix

  1. 1

    Confirm PE ERROR is displayed.

  2. 2

    Check if pressure sensor connector is broken or loose. If YES → reconnect or repair connector.

  3. 3

    If NO → measure resistance of pressure sensor (pin 1 to pin 3); should be 21-23 Ω ±10%. If out of range → replace pressure switch.

  4. 4

    If resistance OK → check if air chamber and tube are clogged. If YES → fix air chamber and remove foreign material.

  5. 5

    If NOT clogged → replace MAIN PWB ASSEMBLY.

This Error Applies To

LG WM8100H Series Washers (2016) (2016–present)

Service manual exact match: WM8100HWAService manual exact match: WM8100HVA