Error Code PE
Pressure Sensor Error
Moderate
Address soon - your appliance may not work properly
What This Means
Pressure sensor assembly out of order; Water level frequency consistently below 10 kHz or over 30 kHz; Pressure sensor connector broken or loose; Pressure sensor resistance out of range (pin 1 to pin 3: 21-23 Ohm +/-10%); Air chamber and tube clogged; Main PWB defective
How to Fix
- 1
Confirm PE is displayed (Note: PE error does not disappear when Start/Pause is pressed; power will turn off within 20 seconds if unresolved)
- 2
Check pressure sensor connector — if broken or loose, reconnect or repair
- 3
Measure resistance of pressure sensor (pin 1 to pin 3) — spec: 21-23 Ohm +/-10% — if out of range, replace pressure switch
- 4
Check if AIR CHAMBER and tube are clogged — if yes, fix air chamber and remove foreign material
- 5
If all above pass, replace MAIN PWB ASSEMBLY
This Error Applies To
LG WM8900H Series Washers (2016) (2016–present)