LG Washers2015–present

Error Code IE

Water Inlet Error

Moderate

Address soon - your appliance may not work properly

What This Means

Water level frequency below 24.6 kHz (air chamber or tube clogged); Filter inlet valve clogged with foreign material; Inlet valve connectors broken or loose; Inlet valve assembly resistance out of range (should be 0.8-1.2 kOhm); Inlet valve connector at MAIN PWB disconnected (NA2, NA4, BL3); Electrical connection issue — replace main harness; Pressure switch defective; MAIN PWB assembly defective; No water tap supply, frozen tap, kinked or leaking supply hose

How to Fix

  1. 1

    Confirm IE is displayed.

  2. 2

    Press Soil + Delay Wash simultaneously to check water level frequency. If below 24.6 kHz, check air chamber and tube for clog.

  3. 3

    If frequency is OK, check if filter inlet valve is clogged — clean or replace filter.

  4. 4

    Check inlet valve connectors for damage or looseness — reconnect or repair.

  5. 5

    Measure resistance between each terminal of inlet valve assembly: should be 0.8-1.2 kOhm. If out of range, replace Inlet Valve Assembly.

  6. 6

    Check voltage at inlet valve connector — should be 120 VAC while power is on. If yes, replace Inlet Valve Assembly.

  7. 7

    Check connector at MAIN PWB (NA2, NA4, BL3) — reconnect or repair if disconnected.

  8. 8

    Verify electrical connection is correct per wiring diagram (page 41). If not, replace Main Harness.

  9. 9

    After reconnecting connector, recheck water level frequency. If still below 24.6 kHz, check Pressure Switch.

  10. 10

    If all above pass, replace MAIN PWB Assembly.

  11. 11

    Installation check: no water tap leakage, no freezing, no hose entanglement, no water shortage, no hose shrinkage, no hose leakage.

This Error Applies To

LG WM9000H Series Washers (2015) (2015–present)

Service manual exact match: WM9000HVAService manual exact match: WM9000HWA